C66U11B Ceiling Fan Receiver for Casablanca
- Fan Model # C66U11B
- Ceiling Fan Receiver
- Fits 1 model
DC fan receiver for the Casablanca C66U11B: swap it in the canopy, pair your RH787T, and run six speeds, reverse and the dimmer again.
$62.95
Ships today from FanRemotes.com
if ordered in the next
- 1-Year WarrantyOn every product
- Same-Day ShippingIn-stock orders by 4 PM
- 90-Day ReturnsSee return policy
- Expert Support(816) 586-8457Mon–Fri, 8 AM – 5 PM CT
Compatible Models
This replacement receiver for the Casablanca C66U11B fits 1 model. Check the model number on your fan’s label.
- C66U11B DC ceiling fan
Not sure it’s the right one? Call (816) 586-8457 or email info@fanremotes.com and we’ll check it against your fan for you.
About the Casablanca C66U11B Receiver
This replacement receiver is made for the Casablanca C66U11B DC ceiling fan. It mounts in the canopy where the old one sat, connects the same way, and learns your RH787T remote during a short setup run after a power cycle.
Your fan's model number is on the motor housing label; when it reads C66U11B, this receiver is made for it. The swap happens at the canopy, then it pairs with your RH787T.
- Works with the RH787T remote (not included)
- Radio frequency (RF) control
- Light on/off and dimming
- Learns your remote in a short pairing step
Receiver or remote: which failed?
Start with the cheap test: put a fresh battery in your RH787T remote. If the fan still ignores every button, and the wall switch and breaker are on, the receiver is the likely culprit. A receiver can also fail partway, running one speed or leaving the light stuck on.
Remote battery tips
The remote battery is not part of this order. If your remote has been weak, fit a new battery before pairing so the learning step goes smoothly. Keep spares in a cool, dry place.
Before you order
- Not for AC-motor Casablanca fans or Casablanca 4-speed universal receiver systems.
- Not a universal receiver. It is made for Casablanca DC fans that came with the RH787T remote.
Setup & Pairing
- Cut power at the breaker panel and confirm the fan is dead.
- Loosen the canopy screws and slide the canopy down to expose the receiver.
- Photograph the wiring, then disconnect the old receiver.
- Connect the replacement receiver the same way, keeping the connections secure, and tuck it neatly back into the canopy.
- Reinstall the canopy and restore power at the breaker.
- Press the Set button on your RH787T within 60 seconds of restoring power, and wait about 5 minutes while the fan runs both ways.
- Check off, all six speeds, reverse and the light.
Tip: a helper on the ground saves trips up and down the ladder.
In the box: Receiver for the C66U11B only; remote not included.
Product Details
| Fan Model | C66U11B |
|---|---|
| Fan Brand | Casablanca |
| Product Type | Ceiling Fan Receiver |
| Made By | Comfort Direct |
| Condition | New |
| Works with | RH787T handheld remote (not included) |
| Motor type | Casablanca DC-motor fans |
| Fan speeds | 6 + off |
| Reverse | Yes |
| Light | On/off and dimming |
| Frequency | Radio frequency (RF) |
| Warranty | 1 year |
| Compatible Models | 1 (see list) |
| Availability | In stock |
| Ships | Same business day if ordered by 4 PM |
| Returns | 90 days on unused items |
Why Buy From FanRemotes.com?
- 1-Year WarrantyEvery product is covered against defects
- Same-Day ShippingIn-stock orders placed by 4 PM ship the same business day
- 90-Day Return PolicyBuy with confidence
- Real Remote Experts(816) 586-8457 · Mon–Fri, 8 AM – 5 PM CT
Frequently Asked Questions
Will this replacement receiver for the Casablanca C66U11B fit my ceiling fan?
It fits the 1 model listed under Compatible Models on this page. If your model isn’t listed, call us at (816) 586-8457 and we’ll check for you.
Is this the receiver for the Casablanca C66U11B?
Yes. It is made for the Casablanca C66U11B DC ceiling fan and pairs with the RH787T remote.
Will my old remote work with it?
Yes, if it is a working RH787T. It pairs with the new receiver in a short learning step.
What if pairing does not work?
Turn the power off and on again, press Set sooner, within 60 seconds, and wait for the fan to stop. If it still fails, call us at (816) 586-8457.
Will it work on an AC-motor Casablanca fan?
No. It is made for Casablanca DC-motor fans only.
Does this come with a remote?
No. It is the receiver only and works with the RH787T remote.
When will my order ship?
In-stock orders placed by 4 PM, Monday to Friday, ship the same business day.
What is your return policy?
You can return items within 90 days. Items must be unused and uninstalled, in their original packaging. No restocking fees. Please read our return policy before sending anything back. Questions? Call (816) 586-8457 or email info@fanremotes.com.
Is there a warranty?
Yes. Every product we sell comes with a 1-year warranty against defects. If it fails because of a defect, contact us and we’ll send a replacement.
Help & How-To Guides
- Casablanca Ceiling Fan Remote: Pairing, Receivers and Fixes
- Ceiling Fan Receiver Replacement: Signs, Testing and Choosing the Right One
- How to Add a Remote to a Ceiling Fan (Pull-Chain Conversion)
- How to Pair a Ceiling Fan Remote: Every Method Explained
- Ceiling Fan Turns On by Itself? Causes and How to Stop It
Related products
-

TG52LW3D1RCS Ceiling Fan Receiver for Harbor Breeze
0 out of 5$33.95 Add to cart -

BRD48MBK6LR Ceiling Fan Receiver for Harbor Breeze
0 out of 5$33.95 Add to cart -

BRD48BNK6LR Ceiling Fan Receiver for Harbor Breeze
0 out of 5$33.95 Add to cart -

TG44BNK3D1RC Ceiling Fan Receiver for Harbor Breeze
0 out of 5$33.95 Add to cart -


458611 Ceiling Fan Receiver for Hampton Bay
0 out of 5$29.95 Add to cart